L180 Enclosed Logger (USB)
DESCRIPTION
The L180 Enclosed Logger is a powerful control unit and a fully programmable data logger with 250 MB memory. USB logging is optional and increases internal memory to 500MB, it collects data from devices such as a controller and can be used in a number of applications.
Logging
250 MB log memory (500 MB + USB optional)
Recording rates up to 1000 samples per second
Fast ethernet download
Includes standard i2 data analysis software (Pro Analysis upgrade available)
Entrances
10 (20 with I / O upgrade *) analog voltage inputs:
4 (8 *) x 0 to 5.46 V, 1.33 mV resolution 6 (12 *) x 0 to 15.0 V, 3.66 mV resolution
4 (8 with I / O upgrade) analog temperature inputs
0 to 15 V, 3.66 mV resolution
4 digital inputs
2 switch inputs
4 speed inputs
Outputs
6 low-side outputs PWM or switching operation
1.0 A max., Current limited and thermally overload safe
expander
Compatible with the expanders E816 and E888 (for the full range of functions)
VIM and SVIM
Internal sensors
3-axis accelerometer, detection range: +/- 5G
Temperature sensor
Sensor supply voltage
Battery voltage
communication
4 configurable CAN buses with individually programmable CAN bus speeds.
One can be used for RS232 reception. Only 2 of the CAN buses support VIM / SVIM expanders.
2 dedicated RS232 ports
Power supply
Operating voltage: 6 to 32 V DC
Operating current: 0.4 A typical at 14 V (without sensor currents)
Reverse polarity protection
Battery transient protection
Sensor supply currents
5 V sensor supply: maximum 0.25 A.
8 V sensor supply: maximum 0.25 A.
operating temperatur
Inside: -20 ° C to 80 ° C
Typical ambient temperature range in free air: -20 ° C to 65 ° C
Physically
Size: 134.5 x 103.9 x 20.2 mm without connector
Weight 343 g
1 x 79-pin Autosport connector